OneCommand™ Manager Application P007997-01A Rev. B
11. Configuring Boot from an FC SAN
Configuring Advanced Settings (Boot from SAN)
191
None
EFIBootFCScanLevel: NVRAM Targets and EFIBootFCScanLevel:
Discovered Targets – Allows 3rd party software to toggle between Boot Path
from NVRAM and Boot Path from Discovered Targets by manipulating an
EFI system NVRAM variable.
Maximum LUNs per Target – Sets the maximum number of LUNs that are
polled during device discovery. The range is 1 to 4096. The default is 256.
Reset Delay Timer in seconds – Sets a value for delay device discovery. The
range is 0 to 255. The default is 0.
PLOGI Retry Timer – Sets the interval for the PLOGI (port log in) retry timer.
This option is especially useful for Tachyon-based RAID arrays. Under very
rare occasions, a Tachyon-based RAID array resets itself and the port goes
offline temporarily in the loop. When the port comes online again the PLOGI
retry interval scans the loop to discover this device.
50 ms
100 ms
200 ms
Default AL_PA number – The range is 0x 00-EF. The default is 0x00. This option
changes the AL_PA (Arbitrated Loop Physical Address) of the selected adapter.
(Not available for OneConnect adapters.)
OpenBoot Advanced Adapter Settings Dialog Box
Use this dialog box to configure the Advanced Adapter Settings for the selected
OpenBoot adapter.
Figure 11-5 OpenBoot Advanced Settings Dialog Box