P007997-01A Rev. B Emulex Connects™ Servers, Storage and PeopleOneCommand™ Manager ApplicationVersion 6.1User Manual
OneCommand™ Manager Application P007997-01A Rev. B List of Figures10List of FiguresFigure 2-1 OCManager Enterprise Installation Options Window...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1005. Click Yes. The Change World Wide Name Configuration dial
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE101Note: If the adapter or firmware does not support Volatile W
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1022. From the discovery-tree, select the adapter port on which
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE103where x is a hexadecimal valueNote: Ensure that a manually e
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1042. From the discovery-tree, select the virtual port you want
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE105Figure 8-23 Delete Virtual Port WarningNote: The link on th
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE106To change the name of an adapter:1. From the discovery-tree,
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE107The following warning appears:Figure 8-24 Reset Warning3. C
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE108Note: This section only applies to FC and FCoE adapters. It
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE109 Figure 8-25 Host Driver Parameters TabHost Driver Paramete
OneCommand™ Manager Application P007997-01A Rev. B List of Figures11Figure 8-18 Maintenance Tab ...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE110 Apply – Click to apply any driver parameter changes. If yo
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE111 Figure 8-26 Driver Parameters Tab – Adapter Selected4. In
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE112Restoring All Parameters to Their Earlier ValuesIf you chang
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE113Setting Driver Parameters for All Adapters in a HostTo chang
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1146. To make a change temporary (the parameter to revert to it
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE115Creating a Batch Mode Driver Parameters FileYou can apply dr
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1163. The Driver Parameter File Selection dialog box appears. S
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE117Checkboxes next to the host and adapter entries are used to
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE118Configuring FCoE Initialization Protocol (FIP)The FIP tab en
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE119the DCB tab). If CIN (Non-FIP) was the current DCBX mode, “A
OneCommand™ Manager Application P007997-01A Rev. B List of Figures12Figure 8-58 Install Feature Licenses Dialog Box...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1202. Select the DCB tab. Figure 8-31 DCB Tab (FCoE Adapter Po
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE121PFC Properties Area State – Enabled means that flow control
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1223. Click Configure DCB. The Configure DCB dialog box appears
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE123LLDP Settings Area Transmit Enabled – LLDP Transmit can be
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI124Configure DCB Dialog Box Buttons Defaults – Click to return p
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1253. Select the iSCSI Port Information tab. Figure 8-33 iSCSI P
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI126TCP/IP Configuration Area DHCP Enabled – The DHCP authentica
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1273. Select the VPD tab. Figure 8-34 OneConnect VPD TabVPD Tab
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI128To view iSCSI port statistics:1. Select Host view.2. Select an
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI129 Last Session Remote Node Name – The iSCSI name of the remote
OneCommand™ Manager Application P007997-01A Rev. B List of Tables13List of TablesTable 5-1 Namespaces Used for Providers...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI130Viewing iSCSI Target InformationWhen you select a target assoc
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI131Target Portal Information Area IP Address – The IP address th
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1322. From the discovery-tree, select the iSCSI LUN whose informa
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI133Viewing iSCSI PCI RegistersThe iSCSI PCI Registers tab display
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1342. Select the DCB tab. Figure 8-39 DCB Tab for iSCSI Adapter
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI135PFC Properties AreaNote: PFC is not supported on all the iSCSI
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1363. Click Configure DCB. The Configure DCB dialog box appears.4
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI137LLDP Settings Area Transmit Enabled – LLDP Transmit can be en
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI138 Bandwidth % – The configured value of bandwidth for the diff
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI139Figure 8-41 Modify TCP/IP Configuration Dialog BoxTo modify T
OneCommand™ Manager Application P007997-01A Rev. B1. Introduction141. IntroductionThe Emulex® OneCommandTM Manager application is a comprehensive mana
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI140Advanced TCP/IP ConfigurationThe Advanced TCP/IP Configuration
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI141Configuring iSCSI Port Initiator Login OptionsThe iSCSI Initia
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI142Initiator Login Options Area ImmediateData – Defines whether
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1433. Click Apply Changes. Note: Any changes to the iSCSI initiat
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC144 DataSequenceInOrder – The order between sequences. HeaderDige
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1453. Select the Port Information tab. Figure 8-45 NIC Port Inform
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC146 Current MTU – The current transmission unit for iSCSI traffic.
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1473. Select the VPD tab. Figure 8-46 OneConnect VPD TabVPD Table
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC148Configuring DCB Parameters for NIC-Only Adapter PortsThe DCB tab
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC149PFC Properties AreaNote: PFC is not supported on all the iSCSI a
OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionCompatibility15 Enable or disable adapter boot (x86 BootBIOS, FCode, EFIBoot, or PXE
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1503. Click Configure DCB. The Configure DCB dialog box appears.4.
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC151LLDP Settings Area Transmit Enabled – LLDP Transmit can be enab
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC152Configure DCB Dialog Box Buttons Configuration Rules – Click to
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1534. Check or uncheck Enable SR-IOV. Figure 8-49 Port Information
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC154The NIC for the discovered guest operating system matches one of
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC155 Operating System – The operating system and version installed
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters156Viewing NIC PCI RegistersThe NIC PCI Registers t
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1572. Select a OneConnect adapter in the discovery-
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters158adapter's temperature and one of the follow
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters159To view general ASIC information:1. Select Host
OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionKnown Issues16OneCommand Manager for VMware vCenter software plug-in. For more detail
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters160 Exceeded operational range – Critical: The ada
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1612. Select a OneConnect multi-ASIC adapter in the
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters162Using the Adapter Information tab, you can view
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters163 Figure 8-57 Licensed Features WindowInstalli
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1643. Following the instructions you received with
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters165 Figure 8-59 OneConnect Adapter Information T
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters166Note: iSCSI and NIC-Only adapters do not appear
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters167 UEFI FCODE – The single flash image containing
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters168Enabling and Disabling OneConnect Physical Ports
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters169Viewing PHY Data (OneConnect 10GBASE-T series Ad
OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionAbbreviations17LPFC LightPulse Fibre ChannelLUN logical unit numberMAC media access c
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters170Error Rates Area Low Density Parity Check (LDPC
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1713. Select the Transceiver Data tab.Figure 8-64
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters172Diagnostic Data Area Temperature – The internal
OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)Linux Considerations1739. Using
OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)Enabling Authentication174lpfc_
OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab175DHCHAP TabThe DHCH
OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab176 Disabled – The a
OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab177Note: To successfu
OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for a Single Adapter17810. Updating Adapter FirmwareT
OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for a Single Adapter1793. Select the Maintenance or F
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters180Updating Firmware for Multipl
OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters181 Figure 10-2 Batch Firmwar
OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters182Figure 10-3 Batch Firmware D
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Types18311. Configuring Boot from an FC SANYou can use the O
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters184Boot Device ParametersThe boot LUN for a
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters185Adapter Boot checkbox and Configure Boot
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters186Note: Topology and link speed are not av
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters187Figure 11-2 Select Boot Device Window (
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)188Configuring Advan
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)189x86 Boot Advanced
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)190interval scans th
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)191 None EFIBootFC
OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)192OpenBoot Advanced
OneCommand™ Manager Application P007997-01A Rev. B12. Exporting SAN InformationCreating a SAN Report19312. Exporting SAN InformationCreating a SAN Rep
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics19413. DiagnosticsDiagnostic tests can only be performed
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics195Viewing Flash Contents, PCI Registers, and Wakeup Inf
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics196Viewing Overlay DetailsIf you double-click on a flash
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics1972. Select the Diagnostics tab and click Quick Test. A
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics198Creating Diagnostic DumpsThe diagnostic dump capabili
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics1994. Click OK. Dump files are created. Where these file
OneCommand™ Manager Application P007997-01A Rev. B 2Copyright © 2003-2012 Emulex. All rights reserved worldwide. No part of this document may be repro
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics200To run advanced diagnostics tests, click Advanced Dia
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics201Loopback Test CombinationsRun the following loopback
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics2022. Select the Diagnostics tab and click Advanced Diag
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics203To run end-to-end echo tests:1. From the discovery-tr
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics204two-line header that contains the identifier of the adapter
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics205 Control adapter beaconing All functions are supported loca
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics206 MAC Loopback – MAC loopback connects the transmit output o
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics2073. Click Start. The following warning appears:Figure 13-13
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics208To enable or disable beaconing:1. From the discovery-tree, s
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics209Creating Diagnostic Dumps The diagnostic dump capabilit
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics210 Linux – /usr/sbin/ocmanager/Dump VMware – a dump director
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations21114. TroubleshootingThere are several circumstances in which
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations212In the OneCommand Manager application discovery-tree, multip
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations213 Unwanted remote servers appear in the OneCommand Manage
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations214Emulex Dr
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations215Under cer
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations216Driver un
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations217Cannot se
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations218 Unwanted
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Solaris and OneCommand Manager Application Situations219Emulex
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingVPorts and OneCommand Manager Application Situations220Port not ready. The contro
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents3Table of ContentsList of Figures ...
OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand
OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationIn Windows313. Starting and Stopping the
OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationIn VMware ESX Server32In VMware ESX Serve
OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationStarting the OneCommand Manager Applicati
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode39Status BarThe sta
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents4Expanding or Collapsing the Discovery-Tree View ...
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode40 Read-only opera
OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode412. Choose the man
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryAutomatic FC Discovery425. Configuring DiscoveryAutomatic FC DiscoveryAdapte
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol43Discovery Using the TCP/IP Acces
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol44 Adding a single host from the
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol45 Blank lines are ignored.3. Sav
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol46 If you want to add the new hos
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol47Figure 5-4 Add Range of TCP/IP
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials48Also, a host can have more than o
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials49host, the adapters of all these h
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents5Adding a Host to a Host Group...
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials50Note: If the Emulex CIM Provider
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery51Configuring iSCSI Target DiscoveryThe iS
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery52Target Discovery Buttons Add Portal – C
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery53Configuring iSNS for iSCSI Target Discov
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery54To discover servers using DHCP, click Di
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery552. Click Target Login. The Target Login
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery56Viewing Target SessionsThe Target Sessio
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery57Note: If all sessions are logged out, th
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery58 iSCSI Boot – Check this box to enable
OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery59 Connection Timeouts – The count of con
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents6Masking and Unmasking LUNs (Windows)...
OneCommand™ Manager Application P007997-01A Rev. B6. Viewing Discovery InformationDiscovery Information Field Definitions606. Viewing Discovery Inform
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsDiscovery Information Field Definitions617. Managing HostsThere are two tabs that s
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsHost Information Field Definitions62Host Information Field Definitions Operating S
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsViewing Host Grouping Information63Viewing Host Grouping InformationThe Host Group
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts64Grouping HostsThe OneCommand Manager application enables you to ass
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts65Managing Host GroupsUse the Host Group Management dialog box to cre
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts66 Remove Host – Removes selected hosts from the currently selected
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts673. Click Yes to delete the selected host group.Adding a Host to a H
OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsSearching for Hosts68the OneCommand installation directory to the equivalent locati
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsUsing CIM698. Managing Adapters and PortsThis section describes the va
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents7Viewing iSCSI PCI Registers...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE702. Select an FC adapter in the discovery-tree. Figure 8-1 FC
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE71 Exceeds operational range – Adapter stopped: The temperatur
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE72FC Port Information Field DefinitionsPort Attributes Area Fie
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE73Loop Map Table Definitions The loop map shows the different
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE743. Select the Port Information tab. Figure 8-3 FCoE Port I
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE75 Firmware Version – The version of Emulex firmware currently
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE763. Click the Statistics tab. Figure 8-4 Statistics TabPort S
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE77 Invalid Tx Words – The total number of invalid words transm
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE78 Total SCSI I/O Count – The number of SCSI I/O requests rece
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE79Virtual Port Information Field Definitions Number of Hosts –
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents8PHY Data Field Definitions ...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE80Viewing FC Transceiver InformationWhen you select an FC port
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE81 Connector – The external optical or electrical cable connec
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE82VPD Table Definitions Product Name – Product information abo
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE833. Select the Maintenance tab. Figure 8-9 FC Maintenance Tab
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE84 “Not Present” if boot code is not loaded. If boot code is n
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE85Viewing FCoE Maintenance InformationUse the Maintenance to vi
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE86 ULP FW Name – The firmware version running on the (Upper La
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE872. In the discovery-tree, select the FC/FCoE target whose inf
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE88 On Linux systems, to make LUNs that are newly added to a st
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE89Mapping Information Area FCP LUN – The FC identifier used by
OneCommand™ Manager Application P007997-01A Rev. B Table of Contents9Running a Quick Test...
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE903. Select the Target Mapping tab.Figure 8-13 Target Mapping
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE91Target Mapping Buttons Refresh – Click to refresh the Target
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE92Target Mapping Buttons N/AMapping and Masking FC and FCoE Po
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE93Figure 8-14 LUN Masking TabLUN Masking Conventions and Guide
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE94To change the mask status of a LUN:1. Select Host view. 2. Fr
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE95Changing Automapping SettingsTo change automapping settings:1
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE962. In the discovery-tree, select the adapter port you want to
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE974. Click Bind New Target. The Bind New Target dialog box is d
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE98 To avoid address conflicts, do not assign a WWNN or WWPN wi
OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE993. Select the Maintenance tab.Figure 8-18 Maintenance Tab4.