TECHNICAL WHITE PAPER / 13
VMware vCloud Director 5.1 Evaluation Guide
Compute Hardware Requirements
The management cluster requires at least one physical host powerful enough to host the virtual machines that
will be deployed. Two ESXi hosts were used for redundancy in the creation of this guide.
The resource cluster requires four physical hosts of sucient power to host two standard Linux virtual machines
at a minimum.
Network Requirements
One physical network is utilized in this guide. This network must have connectivity to external systems used for
testing as well as software download.
The external network must have a pool of IP addresses able to be used for connectivity. It also must have a
Dynamic Host Configuration Protocol (DHCP) server located on it that is able to provide DHCP services as
needed. In addition, it must support multicast packets.
Four IP addresses are required for each of the main virtual machine components, in addition to the addresses
used by the physical hosts themselves. Each address must be resolvable through DNS by a Fully Qualified
Domain Name (FQDN). The following table lists the relevant information used for this guide.
FQDN ROLE NOTES
vc-l-01a.corp.local vCenter Server
to be attached to
vCloud Director
One IP address is required.
vcd-01a.corp.local vCloud Director vCloud Director requires two
network interfaces. One is used
for HTTP trac; the other is used
for the console proxy trac.
The FQDN name should resolve
to the HTTP interface.
vsm-01a.corp.local vCloud Networking and Security
Manager
One IP address is required.
Storage Requirements
The environment used for this guide has three datastores, each 100GB in size, for a total of 300GB of storage
available. They are configured as shared datastores that are available to all hosts used in the evaluation
environment. Various types of storage, including SSD and SAS disks, back these datastores. Although having
dierent types of storage available is not required, it enables users to create multiple tiers of service oerings
based upon the storage type.
To complete the procedures presented in this guide, users must have a minimum of 100GB of storage in a shared
datastore accessible by the hosts in the resource cluster. If they want to deploy a highly available management
cluster, they also must have shared storage accessible by the hosts in the management cluster.
vCloud Director requires that vSphere DRS be enabled in fully automated mode. This requires that shared
storage be attached to all of the hosts, so users must ensure that the storage they employ is visible from all of