NETAPP TECHNICAL REPORT
NetApp Deduplication for FAS and V-Series
Deployment and Implementation Guide
Carlos Alvarez
March 2009 | TR-3505-0309
ABSTRACT
This guide introduces NetApp
®
deduplication for FAS technology, describes in detail how to implement and
use it, and provides information on best practices, operational considerations, and troubleshooting.
It should prove useful for both NetApp and channel partner sales and services field personnel who require
assistance in understanding details and successfully deploying solutions that include deduplication.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - ABSTRACT

NETAPP TECHNICAL REPORT NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide Carlos Alvarez March 2009 | TR-3505-0309 ABSTRAC

Seite 2 - TABLE OF CONTENTS

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 10 Command Summary sis check <vol> (This command is available only

Seite 3

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 11 1. Create a flexible volume (keeping in mind the maximum allowable v

Seite 4

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 12 7. Run deduplication on the flexible volume. These causes the change

Seite 5 - 1.2 DEDUPLICATED VOLUMES

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 13 On flexible volume dvol_2, deduplication is scheduled to run every

Seite 6

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 14 The more concurrent deduplication processes you’re running, the mor

Seite 7 - 2.1 REQUIREMENTS OVERVIEW

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 15 (There are no configurable parameters that can tune the deduplication

Seite 8

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 16 The PAM card has provided significant performance improvements in VMw

Seite 9 - 2.3 COMMAND SUMMARY

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 17 The storage savings may continue to stay low. When the last Snaps

Seite 10

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 18 OVERVIEW OF SSET The SSET is available to NetApp system engineers, in

Seite 11

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 19 Table 5) Maximum deduplicated volume sizes. Data ONTAP 7.2.X (Startin

Seite 12

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 2 TABLE OF CONTENTS 1 INTRODUCTION AND OVERVIEW OF DEDUPLICATION ...

Seite 13

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 20 NUMBER OF DEDUPLICATION PROCESSES A maximum of eight deduplication pr

Seite 14

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 21 4.2 DEDUPLICATION AND SNAPRESTORE The SnapRestore® functionality is

Seite 15

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 22 The cloned volume inherits the deduplication configuration of the p

Seite 16

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 23 The checksum type you can use with deduplication on a V-Series system

Seite 17

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 24 Deduplication can be enabled, run, and managed only from the primar

Seite 18

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 25 As a best practice, NetApp recommends performing qtree SnapMirror upd

Seite 19

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 26 Qtree SnapMirror Replication with Deduplication Enabled on the Destin

Seite 20

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 27 Keep the following points in mind: Deduplication is licensed on bot

Seite 21

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 28 4.11 DEDUPLICATION AND MULTISTORE (VFILER) Starting with Data ONTAP

Seite 22

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 29 impact will be experienced on low-end systems (for example, 30xx) mor

Seite 23

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 3 5 DEDUPLICATION AND VMWARE ...

Seite 24

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 30 Table 7) LUN configuration examples (as described below). A (Defaul

Seite 25

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 31 Note: If Snapshot copies are turned off for the volume (or no copy ex

Seite 26

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 32 Configuration D: LUN Configuration for Maximum Volume Space Savings I

Seite 27

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 33 5 DEDUPLICATION AND VMWARE VMware environments deduplicate extremely

Seite 28

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 34 Figure 7) VMFS data store on Fibre Channel or iSCSI—si

Seite 29 - 4.15 DEDUPLICATION AND LUNS

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 35 5.3 DEDUPLICATION ARCHIVE OF VMWARE Deduplication has proven very us

Seite 30

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 36 7 DEDUPLICATION AND EXCHANGE If Exchange and NetApp deduplication fo

Seite 31

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 37 11 TROUBLESHOOTING This section covers issues that occasionally come

Seite 32

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 38 and are locking a lot of data. This tends to happen especially when d

Seite 33 - 5 DEDUPLICATION AND VMWARE

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 39 11.6 ADDITIONAL REPORTING WITH SIS STAT -1 For additional status inf

Seite 34

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 4 1 INTRODUCTION AND OVERVIEW OF DEDUPLICATION This section provides an

Seite 35

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 40 13 ADDITIONAL ASSISTANCE For additional support contact one of the f

Seite 36

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 5 In summary, this is how deduplication works. Newly saved data on the F

Seite 37 - 11 TROUBLESHOOTING

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 6 Releasing a duplicate data block entails updating the indirect inode p

Seite 38

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 7 1.4 GENERAL DEDUPLICATION FEATURES Deduplication is enabled on a per

Seite 39

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 8 Here are some additional considerations with regard to max volume size

Seite 40 - 13 ADDITIONAL ASSISTANCE

NetApp Deduplication for FAS and V-Series Deployment and Implementation Guide 9 2.3 COMMAND SUMMARY Table 2 describes all deduplication (related) co