VSPEX Configuration Guidelines
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
151
Verify Zone Configuration
SW6510:FID128:admin> cfgshow
Defined configuration:
cfg: vspex ESX_Host_A
zone: ESX_Host_A
ESX_Host_HBA1_P0; VNX_SPA_P0
alias: ESX_Host_HBA1_P0
10:00:00:05:33:64:d6:35
alias: VNX_SPA_P0
50:06:01:60:b6:60:07:c3
Effective configuration:
cfg: vspex
zone: ESX_Host_A
10:00:00:05:33:64:d6:35
50:06:01:60:b6:60:07:c3
SW6510:FID128:admin> cfgactvshow
Effective configuration:
cfg: vspex
zone: ESX_Host_A
10:00:00:05:33:64:d6:35
50:06:01:60:b6:60:07:c3
Follow the above Zoning steps to configure Fabric-B switch.
Following table shows a list of commands that can be used to Manage
and Monitor Brocade Fibre Channel switches in a production environment.
Switch Management Switchshow
Switch Monitoring
1. porterrshow
2. Portperfshow
3. Portshow
4. errshow
5. Errdump
6. Sfpshow
7. Fanshow
8. Psshow
9. Sensorshow
10. Firmwareshow
11. Fosconfig --show
12. Memshow
13. Portcfgshow
14. Supportsave to collect switch logs
Seitenansicht 150